Part Numbers |
|||
|---|---|---|---|
|
S20260-DLS |
Output Current = 1.5A RMS continuous |
||
|
S20360-DLS |
Output Current = 3A RMS continuous |
||
|
S20660-DLS |
Output Current = 6A RMS continuous |
||
|
S21260-DLS |
Output Current = 12A RMS continuous |
||
|
S22460-DLS |
Output Current = 24A RMS continuous |
||
|
Drive I/O Port DC Inputs |
|||
|
Configuration |
*4 optically isolated 24V DC inputs *Active high *Sink or source |
||
|
Guaranteed On |
15 VDC |
||
|
Guaranteed Off |
5 VDC |
||
|
Time delay on |
1 ms max. |
||
|
Time delay off |
1 ms max. |
||
|
Input voltage |
Nominal 24 VDC, maximum 30 VDC |
||
|
Drive I/O Port DC Outputs |
|||
|
Configuration |
*4 optically isolated 24V DC outputs *Active high *Current sourcing only (current into load) *Short circuit and overload protected |
||
|
Maximum current |
50mA per output |
||
|
Voltage range |
24VDC +15%-10% |
||
|
Time delay on for resistive loads |
50 usec. max |
||
|
Time delay off for resistive loads |
50 usec. max |
||
|
Leakage current in off state |
0.5 mA max |
||
|
Digital Link In/Out Ports |
|||
|
"In" port |
Sends and receives high speed data to and from connect-ed MMC-SDs "Out" port. |
||
|
"Out" port |
Sends and receives high speed data to and from connect-ed MMC-SDs "In" port. |
||
|
Cable Type |
Shielded, Straight Pinned, CAT5 or better (CAT5e, CAT6, etc.) |
||
|
Maximum Cable Length |
30 m (98.4 ft) |
||
|
Conformity |
|||
|
CE Marked Note: Only units Rev 1 or higher are CE Marked. |
Conforms to Low Voltage Directive 73/23/EEC (amended by 93/68/EEC) and EMC Directive 89/336/EEC (amended by 92/31/EEC and 93/68/EEC).Conformance is in accordance with the following standards: EN 50178 and EN61800-3 |
||
|
UL and C/UL Recognized |
E233454 |
||
|
RoHs |
The S200-DLS Drives are not RoHs compliant |
||